Home > ETS-P
ETS-P Magnetostrictive displacement sensor
Product Details

ETS-P Magnetostrictive displacement sensor Product advantages:

  • Strong and durable: Fully enclosed design, the highest IP68 protection level

  • Straight line measurement Absolute output, no need to return to zero

  • Easy to use: Standard signal output, maintenance free

  • Never wear: Continuous non-contact measurement

  • Full range adjustable: 100% adjustable zero and full range

  • High resolution: The highest resolution is 0.5um

Technical parameter:

Input:  Measurement data: location、Measurement range: 50mm-7650mm 

Output:Voltage:0~10Vdc,10~0Vdc,0~5Vdc,5~0Vdc(controller minimum load: >5k Ohms)

Electric current: 4~20mA,20~4mA,0~20mA,20~0mA(minimum load: 0 Ohms / heavy load: 500 Ohms)

Accuracy: Resolution 16 bit D / A, up to 0.5um

                   Nonlinearity < 0.02% of full scale (minimum 100um)

                   Repeatability < 0.002% of full scale or the same as resolution

                   Update time 0.5ms (range ≤ 1200mm)、1.0ms (range ≤ 2400mm)、2.0ms (range ≤ 4800mm)、3.0ms (range ≤ 7650mm)

Working conditions: Magnetic ring speed: arbitrary、Working temperature :- 40 ~ 85 ℃

                                    Humidity / dew point humidity :90%, no condensation、Temperature coefficient<30ppm / ℃

                                    Protection grade:IP65 TP aluminum forming outer pipe、IP68 TH pressure resistant outer pipe (waterproof type)

Structure and materials:  Electronic warehouse: Aluminum alloy profiles、Measuring rod: Aluminum alloy

                                           Magnet: Slider magnet or floating magnet、Magnetic ring:Standard magnetic ring or open magnetic ring

                                          Outer pipe pressure:  40MPa (continuous)、60MPa (peak value)

Install:  Installation direction:arbitrary direction、Thread form: metric m18 × 1.5 ,M20 × 1.5、British system 3 / 4 “- 16UNF-3A

Electrical connection: Outlet type: waterproof connector or aviation plug、Input voltage: 24 VDC (- 15 ~ + 20%)、

                                      Polarity protection Maximum :- 30VDC、Overpressure protection: Maximum36VDC

                                      Working current <70mA (varies with measuring range)